Form LinkJob NumberJob CategoryForm DateConvey #Bldg NameInspect TypeInspect StatusRe-inspection Only? Y/NInitial Inspect DateInspector NameMaint CoMaint Co Lic#Mech Lic#General: ID#General Bldg. Rep.General: MAKEGeneral: Job SpecsCOMMENTSCOMMENTS ADDITIONALCounty CheckAddress Check
ViewWO 42413Otis-Springfield2021-11-09 00:00:00H009032202 North Street Condominium AssociationPeriodicFAILNoMike LambrechtOtis3083278078020-RR-2Louie KaterCorbinAnnual Pressure Test-400psi ReliefMake emergency light operable in car3100 Stevenson Dr
ViewWO 40950TK-Peoria2021-07-09 00:00:00T007881309 E John, LLCPeriodicFAILNoTom ClarkThyssenkrupp28963873DebbieKoneAnnual1.6 The in car emergency phone needs to be reprogrammed to a different number, elevator emergency phones shall not call 911. 2.7 The fire extinguisher in the machine room needs to be replaced the one in your machine room needs to be up to date.100 Provena Way
ViewWO 41269KONE-SPR2021-08-04 00:00:00H009842ADM Parking GaragePeriodicFAILNoTom ClarkKone28172536Bobby DavisLong7378702501.6 Make the in car emergency phone and alarm bell operable.Relief -300psiChampaign222 N State St
ViewWO 42474KONE-Moline2021-11-17 00:00:00T004072American BankPeriodicFAILNoMike LambrechtKone28174272CT-36439-Car #2BKim BrownMontgomery725119113-Annual No-LoadMake emergency light operable in car.RockIsland1600 4th Ave
ViewWO 42475KONE-Moline2021-11-17 00:00:00T004073American BankPeriodicFAILNoMike LambrechtKone28174272CT-36438-Car #1AKim BrownMontgomery740168593-Annual No-LoadMake emergency light operable in carRockIsland1600 4th Ave
ViewWO 42071Otis-Evansville2021-10-13 00:00:00H017091America's Best ValuePeriodicFAILNoDeon Firelane308330836347OtisPressure Relief 4601.6 make emergency phone work as intended.904 W Green St
ViewWO 40328TK-Peoria2021-05-19 00:00:00H021895Apostolic Christian ChurchFAILDeon Firelane1.6 make emergency phone work as intended. 2.7 update fire extinguisher.Vermilion3220 Independence Dr
ViewWO 39709KONE-Moline2021-03-23 00:00:00H014458Bethel Wesley Methodist ChurchFAILMike LambrechtMake emergency light operable in car. Replace bad lock on car station.( could not open car station due to a key broken off in lock) Remove all wires not pertaining to elevator from machine room. ( communication wires run in open thru machine room) Certificate expired, must obtain a current certificate within 30 days or elevator company will not be able to service or repair elevator without an extension or permit from State Fire Marshall.RockIsland6501 N Sheridan
ViewWO 40753KONE-SPR2021-06-24 00:00:00H021498Black Chamber of Commerce of IllinoisPeriodicFAILNoBob BeeverKONE28171819CP-53083TammaraMontgomeryRelief 380The phone inside the elevator needs to be repaired to work as intended. 30 DayThe belts on the front door operator.RockIsland1504 3rd Ave
ViewWO 42294Otis-Evansville2021-11-01 00:00:00H017017Bradley - ChoisserPeriodicFAILNoDeon FirelaneOtis Evansville30836347#2 NewKeithOtisPressure Relief 6801.6 make emergency phone and emergency light and bell work as intended.Peoria23207 Townline Rd
ViewWO 42289Otis-Evansville2021-11-01 00:00:00H008627Bradley - Choisser High RisePeriodicFAILNoDeon FirelaneOtis Evansville30836347#1 OldKeithDoverPressure Test 3801.6 make emergency light and bell work as intended. Program emergency phone to call Otis, Emergency phone is calling TK Elevator.RockIsland1110 S 2nd St
ViewWO 40815KONE-SPR2021-06-28 00:00:00T003535Bressmer BuildingPeriodicFAILNoMike LambrechtNoneNoneNone0868-Car #2 CarBJim Mies(KONE)Westinghouse/MCEUnlock And Verify LockoutNeed to have a modernization done before public use8364 Shawnee College Rd
ViewWO 40813KONE-SPR2021-06-28 00:00:00T003541Bressmer BuildingPeriodicFAILNoMike LambrechtNoneNoneNone10508Jim Mies(KONE)Westinghouse/LongUnlock And Verify LockoutCar not running, locked out. Needs to be repaired in numerous places to be operational.McLean703-705 S University St
ViewWO 40814KONE-SPR2021-06-28 00:00:00T003542Bressmer BuildingPeriodicFAILNoMike LambrechtNoneNoneNone0867-Car #1- Car AJim MiesWestinghouse/MCEUnlock And Verify LockoutNeeds to have a modernization done for public use.Champaign200 W International Dr
ViewWO 42395KONE-Moline2021-11-08 00:00:00T004408Cambridge Lutheran ChurchPeriodicFAILNoMike LambrechtKone28176189JohnInclinator740247932-Annual No-LoadSafeties do not work(Make safeties operable) Certificate expired over a year 9/2020. Must obtain an extension or permit from State Fire Marshall for elevator company to service or repair elevator. Elevator left shut off
ViewWO 42301Otis-Evansville2021-11-01 00:00:00H017993Carbondale High SchoolPeriodicFAILNoDeon FirelaneOtis30836347MECOPressure Relief 5001.6 make emergency phone work as intended. 6. Call cancel on phase two fire service not working.2040 53rd St
ViewWO 42040KONE-Champaign2021-10-12 00:00:00T004227Cargill Inc Dry CornPeriodicFAILNoBob BeeverKone28175823South FreightEdMontgomery742097844 5 YearPhone inside the elevator needs to be repaired to work as intended. It appears that the phone line is disconnected. 30 DayMacon115 W Main St
ViewWO 42053Otis-Evansville2021-10-12 00:00:00H022323Carterville High SchoolPeriodicFAILNoDeon FirelaneOtis Evansville30836347Passenger #1OtisBill1.6 make emergency phone work as intended.Kankakee350 N Wall St
ViewWO 42054Otis-Evansville2021-10-12 00:00:00H022758Carterville High SchoolPeriodicFAILNoDeon FirelaneOtis Evansville30836347Gym ElevatorBillOtisPressure Relief 5201.6 make emergency phone work as intended.1051 S Wall St Ste 5
ViewWO 41559KONE-Champaign2021-08-26 00:00:00H019711Caterpillar ChampaignPeriodicFAILNoBob BeeverKONE2817633140938ScottOtis323128610. Relief1.6 The phone inside the elevator needs to be repaired to work as intended. 30 Day. It appears that the phone line has been disconnected. 1.6. The emergency lighting inside the elevator needs to be repaired to work as intended. 30 DayRockIsland405 E 1st St
ViewWO 39254KONE-Moline2021-01-28 00:00:00H012054Center BuildingFAILMike LambrechtMake phone in car operableKankakee3100 Stevenson Dr
ViewWO 41325Otis-Evansville2021-08-10 00:00:00H023297Centralia Elks LodgePeriodicFAILNoDeon FirelaneOtis Evansville30832996OtisPressure Relief 6501.6 make emergency phone work as intended.Champaign1905 S Prairie Winds Dr
ViewWO 41295KONE-Champaign2021-08-06 00:00:00H011151Champaign Urbana Reg Rehab CenterPeriodicFAILNoBob BeeverKONE28172920CP77429TaresaMontgomeryRelief 360The phone inside the elevator needs to be repaired to work as intended. 30 Day
ViewWO 39218KONE-Moline2021-01-27 00:00:00H019230Christ United Methodist ChurchFAILMike LambrechtMake phone in car operableMacon455 N Main St
ViewWO 39219KONE-Moline2021-01-27 00:00:00T008900Christ United Methodist ChurchFAILMike LambrechtMake phone in car operableRockIsland2100 Portland Rd
ViewWO 41672Phoenix2021-09-08 00:00:00H013670Christ's Church Of EffinghamPeriodicFAILNoTom ClarkPhoenix42116005AlecConcordAnnualMake the in car emergency phone operable. Remove items in the machine room that do not associated with the elevator.Relief - 1500psiRockIsland302 Burwash Ave
ViewWO 40788Otis-Evansville2021-06-25 00:00:00H020336City National BankPeriodicFAILNoDeon FirelaneOtis30833014OtisPressure Relief 4501.6 make emergency phone work as intended.RockIsland385 E Oak St
ViewWO 41267KONE-SPR2021-08-04 00:00:00H020916City Of Decatur Water Treatment PlantPeriodicFAILNoTom ClarkKone28172536CP-56869RandyMeco7378702531.6 Make the in car emergency phone operable.Relief - 450psi1202 E Harding Dr
ViewWO 40038KONE-Champaign2021-04-20 00:00:00H011746City Of KankakeeFAILMike LambrechtMust install Braille tags on all floors. Car Door operators are powered off car lighting, must be powered off control power. Make emergency light operable.Edgar616 S Jefferson St
ViewWO 40010KONE-SPR2021-04-19 00:00:00H011787Cougill Senior ApartmentsFAILRick WolfEmergency communication not working. A17.1-2.27.1.1 Tactile identification missing (410 ILCS 30/1 )Coles723 N Oak St
ViewWO 42503TK-Peoria2021-11-19 00:00:00H023823County Market DecaturPeriodicFAILNoDeon FirelaneTK Peoria28962519GinaThyssenKruppPressure Relief 5001.5 make emergency light and bell work as intended.
ViewWO 41985KONE-Champaign2021-10-05 00:00:00NADanville Senior ApartmentsPeriodicFAILNoBob BeeverKONE28172920EK4936NicoleDover323184870 Relief 3301.6 Emergency light and phone inside the elevator needs to be repaired to work as intended. 2.1 There needs to be a fire rated door installed on the elevator machine room which is self closing and locking. 2.1. There is a sump pump drain pipe that needs to be moved to have safe access to the elevator controls. It is a tripping hazard now. 2.3. There needs to be more lighting in the machine room to meet the code Lumens and a light switch installed by the machine room door. 2.3 There needs to be a GFI receptacle installed in the elevator machine room. 2.7 There needs to be installed a ABC fire extinguisher in the elevator machine room. 2.11 There is a sprinkler installed in the elevator machine room,this requires that the main line disconnect be shunt tripped. This is required before activation of the sprinkler allowing water flow. This will also require a heat and smoke detector to be installed in the elevator machine room. All smoke detector will need to be tied into the elevator controls. 2.14 There needs to be a code data plate installed on the elevator controls. More comments on second page.2.37 There needs to a pressure switch installed on the elevator valve. This is do head of the cylinder is above the hydraulic tank. 3.17 There needs to be new door operator belts installed. The belts have cracks and are about to break. 5.1 There needs to be lighting installed in the elevator pit.with a switch located near the pit ladder. The lighting and receptacle there now do not work. 5.1 There needs to be a GFI receptacle installed in the elevator pit and a single receptacle for the sump pump,this is not required to be GFI. 5.1 There needs to be a sump pump cover installed in the elevator pit. 5.1 There needs to be installed a pit stop switch located near the pit ladder. 5.1 Since the access to the elevator pit is in the basement. There needs to be a access door installed which will meet hoistway fire rating code with a electrical switch that will shut the elevator down prior to pit entry. The door must be self closing and locking with a category 1 key.There also must be signage on the door indicating that this is elevator pit entry.Authorized personal only. 5.11. After the cylinder test and during the set test the elevator was moving away from the floor. It appears that the cylinder has a leak in it. This needs to be repaired. Elevator was locked out. Phase 1 Fire recall,there needs to be smoke detectors installed in front of the elevator at each floor for fire recall.They need to be tied into the elevator controls.RockIsland
ViewWO 40035KONE-Champaign2021-04-20 00:00:00H017290Dearborn Business CenterFAILMike LambrechtMust install sump pump in pit(Required by Code)Need to add oil to tankRockIsland363 S Main St
ViewWO 42528KONE-SPR2021-11-22 00:00:00LU001207Decatur Jewelry & AntiquesPeriodicFAILNoBob BeeverKONE28176255XVS 6100651ASamanthaCheneyNo LoadThe drum machine needs some new isolation bushings installed , machine needs to be realigned. 30 Day
ViewWO 39601KONE-SPR2021-03-09 00:00:00T005876Decatur Professional PlazaFAILDeon Firelane1.6 make emergency phone work as intended. Make emergency bell work as intended..Governor pull thru 660. Governor pull up 200. Governor over speed switch switch 240. Governor set 280. 125% brake goodRockIsland129 E Scott St
ViewWO 39598KONE-SPR2021-03-09 00:00:00T006839Decatur Professional PlazaFAILDeon Firelane1.6 make emergency phone work as intended. Make emergency bell work as intended.Governor pull thru 670. Governor pull out 280. Governor over speed switch 240. Governor set 280. 125 % brake good.RockIsland401 19th St
ViewWO 39497KONE-Moline2021-03-01 00:00:00T005617Deere & CompanyFAILMike LambrechtMake phone in car operableIroquois1905 S Prairie Winds Dr
ViewWO 39500KONE-Moline2021-03-01 00:00:00T005618Deere & CompanyFAILMike LambrechtMake phone in car operablePeoria7625 N University St
ViewWO 39501KONE-Moline2021-03-01 00:00:00T005619Deere & CompanyFAILMike LambrechtMake phone in car operableSangamon1701 1st Ave
ViewWO 40874KONE-Champaign2021-07-02 00:00:00D002055Delta Zeta ChampaignPeriodicFAILNoBob BeeverKONE28172920138792DeniesMatotNo Load3.23 The suspension ropes need to be replaced ,broken stands. 30 DayRockIsland4201 22nd Ave
ViewWO 41850KONE-Champaign2021-09-21 00:00:00T007621Eden Supportive LivingPeriodicFAILNoBob BeeverKONE28172920Elevator 3. 20347160KenKONENo Load. 738010943The phone inside the elevator needs to be repaired to work as intended. 30 Day 5.6. The tension switch on the tension sheave, needs to work per code. A17.1. 2.18.7.2. 30 DayLaSalle232 Burwash Ave
ViewWO 41852KONE-Champaign2021-09-21 00:00:00T007622Eden Supportive LivingPeriodicFAILNoBob BeeverKONE28172920Elevator 2 20347159KenKONENo Load 7380109431.6. The phone inside the elevator needs to be repaired to work as intended. 30 Day 5.6. The tension switch on the tension sheave, needs to work per code A17.1. 2.18.7.2 Phase 11 fire service needs to work as intended. The door close buttons need to be activated on fire service. 30 Day Phase 1 Fire service the light in the hallway stays on all the time, this needs to be repaired. 30 Day
ViewWO 41853KONE-Champaign2021-09-21 00:00:00T007623Eden Supportive LivingPeriodicFAILNoBob BeeverKONE28172920Elevator 1 20347158KenKONENo Load. 7380109431.6 The phone inside the elevator needs to be repaired to work as intended. 30 Day 5.6. The A17.1. 2.18.7.2. The switch on the governor tension sheave when tripped needs to run to next floor then take its self out of service. This is for all elevators 1,2,3. 30 Day2070 E 5th St
ViewWO 42052KONE-SPR2021-10-12 00:00:00H015627Emling FloristPeriodicFAILNoMike LambrechtKone28172920324063Linda EmlingOtis740249510-320psi ReliefMake phone in car operablePeoria480 W Polk Ave
ViewWO 39372KONE-Champaign2021-11-02 00:00:00H020052First Christian ChurchFAILMike LambrechtMake phone in car operablePulaski200 S 9th St
ViewWO 42404KONE-SPR2021-11-09 00:00:00H007281First Christian Church-BloomingtonPeriodicFAILNoMike LambrechtKone28172920E96855Maggie BurtonDover744207469-430psi ReliefRepair sump in pit to remove water in pit. Also sump pump cannot be plugged into a GFCI.Pulaski200 S 9th St
ViewWO 40418KONE-Peoria2021-01-06 00:00:00H007463First Presbyterian ChurchFAILBob Beever1.6 The emergency lighting needs to be repaired to work as intended. 30 DayJackson
ViewWO 42181KONE-Champaign2021-10-21 00:00:00H011340First Site ApartmentsPeriodicFAILNoBob BeeverKONE281729204732SeanMontgomery742263837 Relief 3602.30. Oil under the pumping unit needs to be cleaned out. 30 Day 3.2 The car top light needs to work as intended. 30 Day 3.16. The travel cable outer jack is completely broken , exposing wires. This needs to be replaced. This appears to be caused by oil and water in pit. 30 Day 5.1 The oil and water in pit needs to be removed and drain opened up to work. 30 Day 5.1 There is a light switch for the stop switch , this needs replaced with a pit stop switch marked pit stop. And red switch.Champaign600 N College Ave
ViewWO 40817KONE-Champaign2021-06-29 00:00:00H014262First United Methodist ChurchPeriodicFAILNoBob BeeverKONE28172920323985DanielleOtisRelief 380The state is requiring that there be tactical identification installed on all the door frames at each floor on both sides of the door frame. Also inside the elevator on the call buttons,door open button and alarm and stop switch. 30 DayRockIsland8001 51st St W
ViewWO 41460TK-Peoria2021-08-19 00:00:00H024785Flourishes Gallery And StudiosPeriodicFAILNoTom ClarkThyssenkrupp28962519CarolThyssenkruppAnnual1.6 Make the in car emergency phone operable.Relief - 430psiChampaign1713 3rd Ave
ViewWO 40284Schindler2021-05-13 00:00:00T007928Fox River ResortFAILMike LambrechtMake phone in car operable(1.6)Sangamon1713 3rd Ave
ViewWO 42524KONE-Moline2021-11-22 00:00:00H001895Friendship ManorPeriodicFAILNoMike LambrechtKone28171552CP-52739- Nurses CenterScott SteinerMontgomery745603877-320psi ReliefReplace flexible hose under tank in machine room (leaking excessively)Must display a current certificate in car
ViewWO 42496KONE-Moline2021-11-19 00:00:00H018824GenerationsPeriodicFAILNoMike LambrechtKone28171552CP-32227-Car #2 East KitchenAmie BehrensMontgomery713816269-380psi Relief24hr two way communication is required in carRockIsland2545 24th St
ViewWO 42497KONE-Moline2021-11-19 00:00:00H018823Generations - Rock IslandPeriodicFAILNoMike LambrechtKone28171552CP-32226-Car #1 West BasementAmie BehrensMontgomery743985986-400psi ReliefRockIsland2545 24th St
ViewWO 40189KONE-SPR2021-05-04 00:00:00SPPEGuldenFAILBob Beever3.20. The governor rope is rouged top to bottom it needs to be replaced. 3.22 The shackles are rusted and need to be replaced, both car and counterweight side. 3.23. The suspension ropes are rouged,need to be replaced. Recommend using cable lube on new cables to help protect cable from the rough environment. 4.2 The bottom hoistway door frame is broken at the bottom and needs to be reattached. 4.2 The 5th floor interlock needs to be repaired to release hoistway door so you can exit elevator. The electrical is working fine.RockIsland1528 3rd Ave
ViewWO 41375KONE-Champaign2021-08-16 00:00:00T002162Hendrick HousePeriodicFAILNoBob BeeverKONE28172920605304 Elevator 4JayvonOtisFive Year Pull Thru 850 Gov Switch 370 Gov Trip 4501.6 The phone inside the elevator needs to be repaired to work as intended. 30 Day 1.6 The emergency lighting inside the elevator needs to be repaired to work as intended. 30 Day 3.23 The suspension ropes need to be replaced. They are rouged and undersized. 30 DayThere needs to be a capacity plate installed inside the elevator. Maintenance provider and customer information. The fire service switch in the hall is cracked needs to be replaced. Maintenance provider information.RockIsland111 20th St
ViewWO 42188Schumacher2021-10-22 00:00:00H013025Hill And Valley Premium BakeryPeriodicFAILNoMike LambrechtSchumacher29004562CP-45282Scott ChristiansenMontgomeryAnnual Pressure Test-500psi ReliefReplace bad shutoff valve in pit and two bad victaulic couplingsRecommend cleaning pit while car is out of serviceRockIsland111 20th St
ViewWO 41503KONE-Champaign2021-08-23 00:00:00H009841Horizon HobbyPeriodicFAILNoBob BeeverKONE28172920CP-60708ScottMontgomeryRelief 3901.6. The phone inside the elevator needs to be repaired to work as intended. 30102 E Chalmers St
ViewWO 41998KONE-Peoria2021-10-06 00:00:00H018993House Of HopePeriodicFAILNoRick WolfKone28175758CP82857MontgomeryEmergency light and alarm not working. Restrictor not working. Clean oil out of pit.Champaign
ViewWO 39469KONE-Moline2021-02-24 00:00:00T002436IH Mississippi Valley Credit UnionFAILMike LambrechtMake phone in car operableHenry319 W Court St
ViewWO 41207KONE-Champaign2021-07-29 00:00:00H005388Illinois Valley Community HospitalPeriodicFAILNoMike LambrechtKone281729201371-Car #10Mikel MathiasFairhall735947901-410psi ReliefCannot run the door re-Opening device off of car lighting. Car lighting disconnect in machine room must be fused and lockableMadison
ViewWO 41205KONE-Champaign2021-07-29 00:00:00T002686Illinois Valley Community HospitalPeriodicFAILNoMike LambrechtKone28172920Car #7Mikel MathiasMontgomery735947901-Annual No-LoadReplace bad roller on top of counterweight frame. Replace all rusted out emt conduit in pit.Macon825 N Rutledge St
ViewWO 41206KONE-Champaign2021-07-29 00:00:00T002694Illinois Valley Community HospitalPeriodicFAILNoMike LambrechtKone28172920Car #8Mikel MathiasMontgomery735947901-Annual No-LoadMake phone in car operable (Speaker not working)RockIsland545 Avenue Of The Cities
ViewWO 41879KONE-Champaign2021-09-22 00:00:00H007456Iroquois Mental Health CenterPeriodicFAILNoBob BeeverKONE28172920Elevator 1RobertGallaher & Speck740249508 Relief 430It appears that the hydraulic cylinder has a hole in it, elevator moved 8” inches with in a couple of minutes with shut off in machine room closed. There was no apparent oil loss in the elevator pit. Elevator has been pad locked off until repairs have been made. 30 Day This was discovered during set test.RockIsland545 Avenue Of The Cities
ViewWO 41502KONE-Moline2021-08-23 00:00:00H012300John Deere Parts Distribution CenterPeriodicFAILNoMike LambrechtKone28171552CP-14502-Office HydroLynn EllisMontgomery739364816-390psi ReliefMust install Braille tags on all floors on hall jambsChampaign
ViewWO 39829KONE-Champaign2021-04-02 00:00:00H015030Justin Kirby Northwestern MutualFAILRick WolfMake emergency phone work properly A17.1-2.27.1.1 Make emergency lights and alarm work properly A17.1-2.27.1.1.5Champaign222 N State St
ViewWO 41783KONE-Champaign2021-09-15 00:00:00H022001Kappa Delta Rho (GM)PeriodicFAILNoBob BeeverKONE28172920EAH867DaveThyssenKrupp740970941 Relief 2851.6. The phone inside the elevator needs to be repaired to work as intended. It appears the phone may need to be reprogrammed. 30 DayChampaign222 N State St
ViewWO 41770TK-Indy2021-09-15 00:00:00H013908Liberty Lane EstatesPeriodicFAILNoTom ClarkThyssenkrupp28963057TammyThyssenkruppAnnual1.6 Make the in car emergency phone operable.Relief - 420psiPeoria3415 N Sheridan Rd
ViewWO 41226Otis-Evansville2021-07-29 00:00:00H022433Marion CentrePeriodicFAILNoDeon FirelaneOtis Evansville30832996#1 PassengerOtisPressure Relief 4501.6 make emergency phone work as intended.Champaign1110 S 2nd St
ViewWO 39628KONE-Champaign2021-12-03 00:00:00H009029Merche ManorFAILTom Clark4.5 The top and bottom floor hoistway access needs to work.Relief - 350psiRockIsland1317 3rd Ave
ViewWO 41718KONE-Moline2021-09-13 00:00:00H015119Milan Municipal BuildingPeriodicFAILNoMike LambrechtKone2817155220264457- PassengerStephen MollerKone739745687-550psi ReliefMake phone in car operableSangamon350 N Wall St
ViewWO 40266KONE-Moline2021-12-05 00:00:00T004873Modern Woodmen Of AmericaFAILMike LambrechtMake rope gripper operableGov Sw 425fpm, Trip 450fpm, PullthruMacon247 E North St
ViewWO 42242Phoenix2021-10-27 00:00:00Not RegisteredNashville Grace United Methodist ChurchPeriodicFAILNoDeon FirelanePhoenix42116005John KennedyInclinatorPre inspection for acceptanceDouglas1600 1st Ave E
ViewWO 39150TK-Peoria2021-01-20 00:00:00H005684One Main PlaceFAILTom Clark1.6 Make the in car emergency phone operable.211 E Armory Ave
ViewWO 39149TK-Peoria2021-01-20 00:00:00T005593One Main PlaceFAILTom Clark1.6 Make the in car emergency phone operable.Sangamon
ViewWO 42349KONE-Peoria2021-11-04 00:00:00T003893OSAf St. Francis Medical CenterPeriodicFAILNoRick WolfKone28274766C38844 #11BretDoverFailed 125% Brake test. Elevator would not run with full load on it. Full load safety test and brake test needs to be done yet. Everything else was good.Kankakee
ViewWO 41710KONE-Peoria2021-09-11 00:00:00H016021OSF Healthcare Pediatric RehabilitationPeriodicFAILNoRick WolfKone28174766EX4960BenThyssenkrupp724988829Emergency communication not working. Fire extinguisher out dated. Remove water in pit.602 N 1st St
ViewWO 41713KONE-Peoria2021-09-11 00:00:00H008800Osf Healthcare SystemPeriodicFAILNoRick WolfKone28174766CP 63244BretMontgomery724988829Emergency alarm not working ( 1.6 )McLean401 W Jefferson St
ViewWO 39313KONE-Champaign2021-02-03 00:00:00T001740Osf Heart Of Mary Medical CenterFAILRick WolfNo crosshead data tag 3.37, phase 2 fire service call cancel and hold not working. Phone box door needs a handle could not open it without a screwdriver.Coles1710 Wabash Ave
ViewWO 41135KONE-Champaign2021-07-23 00:00:00H016202OSF Saint Elizabeth Medical CenterPeriodicFAILNoMike LambrechtKone2817120620240237-MOB #1Bret BailliezKone735140637-600psi ReliefPer code must install sump pump in pit(elevators with fire service must have a sump pump in pit)RockIsland601 S 1st St
ViewWO 41314KONE-Peoria2021-08-07 00:00:00H008798Osf Saint Francis Medical CenterPeriodicFAILNoRick WolfKone28174766CP-143263 - #55BretMontgomeryFailed emergency communicationChampaign1300 River Dr
ViewWO 41281KONE-Peoria2021-08-05 00:00:00H008834Osf Saint Francis Medical CenterPeriodicFAILNoRick WolfKone28174766CP-HH-92847 - #51BretMontgomery/Kone724988826Emergency communication bad. A17.1-2.27.1.1RockIsland3900 28th Drive
ViewWO 42526KONE-Champaign2021-11-22 00:00:00H016480OSF St. Joseph Medical CenterPeriodicFAILNoTom ClarkKone281729209 #1 SterileRay CurryOtis7442878501.6 Make the in car emergency phone operable.Relief - 780psiMcLean2200 E Washington St
ViewWO 42525KONE-Champaign2021-11-22 00:00:00H016481OSF St. Joseph Medical CenterPeriodicFAILNoTom ClarkKone2817292010 #2 SterileRay CurryOtis7442878501.6 Make the in car emergency phone operable.Relief - 610psiMcLean2200 E Washington St
ViewWO 41165KONE-Moline2021-07-26 00:00:00H010033Paddock BuildingPeriodicFAILNoMike LambrechtKone2817218620074994Judy FreemanKONE735368068-490psi ReliefReplace door operator belt. Make phone in car operable. Must install sump pump in pit per A17.1-2.2.2.5. All elevators with fire service must have a sump pump in pit109 N Mattis Ave
ViewWO 42078KONE-Moline2021-10-14 00:00:00H019558PFG-Thoms-Proestler CompanyPeriodicFAILNoMike LambrechtKone28171552CP-75946Todd SmithMontgomery740168580-440psi ReliefRemove all items from machine room that do not pertain to the elevator.Champaign202 N Schuyler Ave
ViewWO 40968KONE-Champaign2021-07-12 00:00:00T005008Pi Kappa PhiPeriodicFAILNoBob BeeverKONE2817292020235555TomKONENo Load1.6 The phone inside the elevator needs to be repaired to work as intended. 30 Day The main floor smoke detector needs to be repaired , the elevator stays on alternate floor recall. 30 Day After test elevator was turned off until repairs can be made.The door close button needs to be replaced. Works part time. The sump pump pipe needs to be repaired to stop leak when it turns on.Kankakee411 W Division St
ViewWO 41548TK-Peoria2021-08-25 00:00:00H023824Precision PlantingPeriodicFAILNoTom ClarkThyssenkrupp28962477DustinThyssenkruppAnnual1.6 Make the in car emergency phone operable.Relief - 400psi
ViewWO 39619TK-Indy2021-11-03 00:00:00H015867Prospect BankFAILDeon Firelane1.18 car doors must be restricted from opening within 18” from door zone.Vermilion1425 E 400 North Rd
ViewWO 42031Otis-Evansville2021-10-11 00:00:00H016945Public Eye InvestorsPeriodicFAILNoDeon FirelaneOtis Evansville30836347KentOtisPressure Relief 5001.6 make emergency light and bell work as intended.
ViewWO 39820Otis-Evansville2021-04-01 00:00:00H022208Quality Inn And SuitesFAILDeon FirelaneChampaign400 S Vine St
ViewWO 40844KONE-STL2021-06-30 00:00:00H03988Richland County Housing AuthorityPeriodicFAILNoDeon FirelaneKone STL28172605Sunshine VillageDoverPressure Relief 3201.6 make emergency phone work as intended.St
ViewWO 40125Stuard2021-04-28 00:00:00HL002812Ridgewood ElementaryFAILMike LambrechtMake stop switch and alarm operable in car. Make under platform obstruction device operable. ( all are unplugged from car) Lift will not run from inside car. Failed for same reason last inspection in 2019. Certificate of operation expired 2018. Elevator company cannot service or repair elevator without an extension or permit from State Fire Marshall. Notice of expiration sent to State Fire Marshall. No certificate displayed on unit.Massac27th St & Pershing Rd
ViewWO 42120KONE-Moline2021-10-18 00:00:00T005530Ridgewood TowersPeriodicFAILNoMike LambrechtKone2817427220017587-Car #1 Large CarAmber TittleKone699075117-Annual No-LoadMake rope gripper operable. Make door restrictor operableMacon131 N Water St
ViewWO 42119KONE-Moline2021-10-18 00:00:00T005531Ridgewood TowersPeriodicFAILNoMike LambrechtKone2817427220017591-Car #2-Small CarAmber TittleKone699075271-Annual No-LoadMake car door restrictor operable.Need fire service test log and service logs on siteKankakee904 W Green St
ViewWO 42490KONE-Moline2021-11-18 00:00:00H008301River StationPeriodicFAILNoMike LambrechtKone28171552443192-Car #1Marcia MitchellOtis746461426-410psi ReliefMake phone in car operableRockIsland1601 River Dr
ViewWO 41945TK-Peoria2021-09-28 00:00:00H010112River Valley BuildingPeriodicFAILNoMike LambrechtThyssenKrupp28962477E46704Mike LandwirthDoverAnnual Pressure Test-380psi ReliefInstall Braille tags on all floors hall jambs, and replace missing Braille on car station. Should display copy of certificate in carKankakee801 Tech Dr
ViewWO 41701KONE-Champaign2021-09-13 00:00:00T003299Riverside Medical CenterPeriodicFAILNoBob BeeverKONE28172920Elevator 3SeanDover7380181193.23 The suspension ropes need to be replaced, they are undersized. 30 DayDouglas600 East Ficklin St
ViewWO 39889KONE-Peoria2021-04-07 00:00:00HL001788Rivian AutomotiveFAILBob BeeverThe needs to be more brackets installed in the hoistway to restrict the car door from being opened from inside the elevator. The final limits and normal stopping limits need to be alike so they can activate of the one cam. They have been replaced with other switches they will not work as intended. There is a governor switch but it has not been wired up this needs to work as intended. A17.1 5.2.1.44. The safety bar on top off car needs to be installed for maintenance and inspection. This will allow refuge space on the top of the elevator. There needs to be a a flow control ( rupture valve) installed in the oil line to prevent down ward movement in case of hose failure or oil line failure. The five year test still needs to be completed.Jackson405 W Jackson St
ViewWO 40883KONE-Moline2021-07-06 00:00:00HL021979Rock Island Center For Math And SciencePeriodicFAILNoMike LambrechtKone28171552E9691-1Dewinn HumeSchindler699074400-500psi ReliefMake phone in car operable. After 30 days elevator company will not be able to service or repair elevator without an extension or permit from State Fire Marshall.Marion400 N Pleasant Ave
ViewWO 41797KONE-Moline2021-09-16 00:00:00T005299Rock Island City HallPeriodicFAILNoMike LambrechtKone2817427220000882Melody MillerKone715636109Make rope gripper operable. Make phone in car operableWilliamson269 W Eldorado St
ViewWO 41836KONE-Moline2021-09-20 00:00:00H017271Rock Island County JailPeriodicFAILNoMike LambrechtKone28171552CP-51011-#2-MaintenanceChuck HauserMontgomery739852663-305psi ReliefReplace bad traveling cable (Bad break under car)Clean up oil on floor in machine room. Clean pit.Marion
ViewWO 41841KONE-Moline2021-09-20 00:00:00H017272Rock Island County JailPeriodicFAILNoMike LambrechtKone28171552CP-51012-#3 VisitorChuck HauserMontgomery /KONE739852664-460psi ReliefMake phone in car operable. New phone line in machine room must be in conduitMacon205 S State St
ViewWO 41826KONE-Moline2021-09-20 00:00:00H017274Rock Island County JailPeriodicFAILNoMike LambrechtKone28171552CP-140380-Car #3 C InmatesChuck HauserMontgomery /KONE741953128-300psi ReliefReplace Drive belt on Door operator. Make emergency light operable in car.replace car door gibs(door has a lot of play)Marion400 N Pleasant Ave
ViewWO 42173KONE-Moline2021-10-21 00:00:00T006348Rock Island County Justice CenterPeriodicFAILNoMike LambrechtKone28174272CT-140379-Car #4DChuck HauserKone741953053-5yr Full LoadMake door re-opening device work correctlyGov Sw 420fpm, Trip 450fpm, Pullthru 450lbs
ViewWO 42082KONE-Moline2021-10-14 00:00:00H007572Rock Island Public LibraryPeriodicFAILNoMike LambrechtKone28171552CP-55041Malachi KohlweyMontgomery739745689-290psi ReliefReplace bad door operator drive belt on front door operator.
ViewWO 40032KONE-Peoria2021-04-20 00:00:00H023768Rohan Products LLCFAILRick WolfCar gate reversing boot broke. Wire and rubber boot needs replaced.350 N Wall St
ViewWO 42064KONE-Moline2021-10-13 00:00:00H010804Sanders ApartmentsPeriodicFAILNoMike LambrechtKone28171552CP-41249Paula LesterMontgomery739745688-300psi ReliefMust install Braille tags on all floors hall jambs. Certificate expired 11/15/2018. Elevator company cannot service or repair elevator without an extension or permit from State Fire Marshall.Champaign309 W Green St
ViewWO 41564KONE-SPR2021-08-26 00:00:00H00903Sangamon County Detention CenterPeriodicFAILNoRick WolfKone28172850#1 North BByronMontgomery739291483Emergency light not working. Fire service jewel in car needs replaced.Saline215 S Mckinley St
ViewWO 41565KONE-SPR2021-08-26 00:00:00H010902Sangamon County Detention CenterPeriodicFAILNoRick WolfKone28172850#2 South CByronMontgomery739291483Emergency light not working. Fire service jewel in car needs replace. Pump motor belts bad need replacedSaline160 Dewey Rd
ViewWO 41568KONE-SPR2021-08-26 00:00:00T004368Sangamon County Detention CenterPeriodicFAILNoRick WolfKone28172850CTX-64921 #5BByronMontgomery739291483Emergency communication bad. Emergency light not working.Wayne108 E Delaware St
ViewWO 41570KONE-SPR2021-08-26 00:00:00T004526Sangamon County Detention CenterPeriodicFAILNoRick WolfKone28172850CT-64922 #6CBryonMontgomery739291483Fire service phase 2 not working. Emergency light not working. Hoistway acces top floor not working. Governor has bad bearing needs replaced.Saline160 Dewey Rd
ViewWO 42482KONE-Champaign2021-11-18 00:00:00T008560Sarah Bush Lincoln Health CenterPeriodicFAILNoBob BeeverKONE28172203639464 H1 ElevatorDarrylOtis743987666 No Load3.23. The suspension belts need to be replaced. 30 Day
ViewWO 39302TK-Peoria2021-02-02 00:00:00H023470Savoy 16 IMAXFAILTom Clark1.6 Make the in car emergency phone operable.Relief -460psiPerry5700 State Route 154
ViewWO 40080TK-Peoria2021-04-22 00:00:00H020643Schnuks Champaign #707FAILTom Clark1.6 Make the in car emergency phone operable.Relief -520psiJackson1301 E Walnut
ViewWO 41490KONE-STL2021-08-20 00:00:00H006909Shawnee CollegePeriodicFAILNoDeon FirelaneKone STL28171910Stage LiftDon KochConcordAnnual10.2.2.4b top floor hall door lock not working properly. Repair or replace to work as intended.Champaign600 N College Ave
ViewWO 41489KONE-STL2021-08-20 00:00:00H020655Shawnee CollegePeriodicFAILNoDeon FirelaneKone STL28101910L BuildingDon KochOtisPressure Relief 5401.6 make emergency phone work as intended.Peoria2806 N Knoxville Ave
ViewWO 42139KONE-STL2021-10-19 00:00:00H001469SIH Memorial Hospital Of CarbondalePeriodicFAILNoDeon FirelaneKone STL28171910#19 Garage WestDennisDoverPressure Relief 3401.18 make car door restrictor work as intended.Macon27th St & Pershing Rd
ViewWO 42123KONE-STL2021-10-18 00:00:00T008023SIH Memorial Hospital Of CarbondalePeriodicFAILNoDeon FirelaneKone STL28171910#17DennisKoneAnnual No Load1.6 make emergency phone work as intended.Williamson1406 W Grand Ave
ViewWO 42124KONE-STL2021-10-18 00:00:00T008024SIH Memorial Hospital Of CarbondalePeriodicFAILNoDeon FirelaneKone STL28171910#18DennisKoneAnnual No Load1.6 make emergency phone work as intended.Peoria530 NE Glen Oak Ave
ViewWO 42295Otis-Evansville2021-11-01 00:00:00H004348Sneed High RisePeriodicFAILNoDeon FirelaneOtis Evansville30836347#1 OldKeithDoverPressure Relief 4001.6 make emergency phone and emergency light and bell work as intended.Williamson1406 W Grand Ave
ViewWO 42143KONE-Moline2021-10-19 00:00:00T002863Spencer TowersPeriodicFAILNoMike LambrechtKone2817427220017551-Car #2 Small CarDebra GovainKone719281109-Annual No-LoadMake phone operable in car. Make emergency light operable in car.( alarm works, no light)Williamson11717 Route 37
ViewWO 42147KONE-Moline2021-10-19 00:00:00T002864Spencer TowersPeriodicFAILNoMike LambrechtKone2817427220017547-Car #1 Large CarDebra GovainKone742686218-Annual No-LoadReplace hoist cables(rouged and undersized)Kankakee1617 2nd Ave
ViewWO 41418KONE-Peoria2021-08-17 00:00:00D001747St Mary's Regional CenterPeriodicFAILNoBob BeeverKONE28172920549142AnnekateWaupacaNo Load3.23. The suspension rope needs to be replaced, there is a Valley break in one spot which fails cable. 30 DayWashington52 S Third St
ViewWO 42351KONE-STL2021-11-04 00:00:00H003259St. Mary's Hospital - CentraliaPeriodicFAILNoTom ClarkKone28172605PCUKelli AdamsDover7453965091.10 Make the rear car door opening operate as intended by code. 1.18 Make the rear door restrictor operable.Relief - 340psiMcLean202 N Center St
ViewWO 42354KONE-STL2021-11-04 00:00:00T001773St. Mary's Hospital - CentraliaPeriodicFAILNoTom ClarkKone28172605#3 WestKelli AdamsMeco7453965092.19 The machine bearing needs replaced as soon as possible. Worm gear is going bad.Champaign
ViewWO 42035Otis-Evansville2021-10-11 00:00:00H024124St. Michael Catholic ChurchPeriodicFAILNoDeon FirelaneOtis Evansville30836347JerryOtisPressure Relief 4501.6 make emergency phone and emergency light work as intended.Williamson1527 Champions Dr
ViewWO 40308KONE-Peoria2021-05-18 00:00:00T006272State Shapiro Development CenterFAILBob Beever3.23. The suspension ropes are rouged and undersized. 30 Day
ViewWO 40406KONE-Champaign2021-05-27 00:00:00H004561Steer PlaceFAILBob BeeverThe rear door needs to be repaired to work as intended. Will not work on phase 11 fire service. 30 Day 2.32 The control valve needs to be replaced or replaced. Oil seeping through valve relieving about every three minutes. 30 DayRockIsland530 NE Glen Oak Ave
ViewWO 40407KONE-Champaign2021-05-27 00:00:00H005361Steer PlaceFAILBob Beever2.35. The shut off in the machine room is frozen and needs to be replaced, the Vic seals on the shut off are leaking oil , needs new seals. 30 Day 5.11. The elevator moved 1/2 inch with pit shut off closed. Could not see any leakage. It was reported that 15 gallons of oil was added not long ago. The needs to be a set test done with weight to see if they can determine where the oil is going. Elevator is shut off until test is done. 30 DayRockIsland350 44th St
ViewWO 42087Otis-Evansville2021-10-14 00:00:00H023103TCT StudiosPeriodicFAILNoDeon FirelaneOtis Evansville30836347RoyceOtisPressure Relief 5751.6 make emergency phone and emergency light and bell work as intended.177 W Wood St
ViewWO 41421KONE-Moline2021-08-18 00:00:00T003985The Stern CenterPeriodicFAILNoMike LambrechtKone28174272CS-19712-Car #2 SouthBill HealyMontgomery/Otis702827762-5yr Full LoadReplace missing Braille tags in car. Must install sump pump in pit to keep pit dry. Must install a remote set/reset governor (Governor located in hoistway at top, not accessible) must display a copy of the certificate of operation in the car.After 30 days the elevator company will not be able to service or repair elevator without an extension or permit from State Fire MarshallPeoria6600 44th Ave
ViewWO 41433KONE-Moline2021-08-18 00:00:00T003989The Stern CenterPeriodicFAILNoMike LambrechtKone28174272CS-19711-Car #1 NorthBill HealyMontgomery/Otis702827731-5yr Full LoadReplace missing Braille tags in carAfter 30 days elevator company will not be able to service or repair elevator without an extension or permit from State Fire MarshallMacon247 E North St
ViewWO 42204KONE-SPR2021-10-25 00:00:00T005786Theater 7PeriodicFAILNoDeon FirelaneKone Springfield281762559700 Car#1MECO743037857
ViewWO 39721KONE-Moline2021-03-23 00:00:00H008945TR HoldingsFAILMike LambrechtMake phone in car operable.802 W Oregon St
ViewWO 40142KONE-Moline2021-04-29 00:00:00H008865Two Rivers YMCAFAILMike LambrechtMust install Braille tags on all floors hall and in car. Must recharge fire extinguisher in machine room ( last date 2018)Recommend install light edge system on car doors to reopen doors upon obstruction1202 E Harding Dr
ViewWO 40644KONE-Champaign2021-06-17 00:00:00HL001690Unitarian Universalist ChurchPeriodicFAILNoTom ClarkKone28172920TimElevette73495475010.2.2.1e Make the emergency light and alarm operable. 10.2.2.1f Repair the front car gate. There is an opening at the bottom of the gate. 10.2.2.1e Make the in car emergency phone operable. The phone calls F.E. Moran but it does not establish two way communications.Massac
ViewWO 40323Otis-Davenport2021-05-19 00:00:00H015869Unity Point-350 John Deere Rd BldgFAILMike LambrechtClose in and fireproof top of hoistway (open to entire building) finish drywalling machine room for fire rating. Repair sump pump in pit and remove waterMcLean1201 13th St
ViewWO 39691KONE-Moline2021-03-23 00:00:00H023802Vibrant Bank MolineFAILMike LambrechtMake phone in car operable. Smoke and heat detectors must be tested once new system is installed.Jefferson2118 E 5th St
ViewWO 41551TK-Peoria2021-08-26 00:00:00H006221West Main BuildingPeriodicFAILNoTom ClarkThyssenkrupp28963873MikeMecoAnnual1.6 Make the in car emergency light and alarm operable.Relief - 300psiRockIsland1401 3rd Ave
ViewWO 42470KONE-SPR2021-11-17 00:00:00H009623Westminister VillagePeriodicFAILNoDeon FirelaneKone Springfield28172920Social Center #1AnthonyFairhall744287846 (PR310)1.6 make emergency light work as intended.1.1 car doors reopen device should not be powered by car lighting circuit. Correct before next inspection.McLean2025 E Lincoln St
ViewWO 39763Barnard2021-03-25 00:00:00H019309WingateFAILDeon Firelane1.5 replace missing ceiling tile. 1.18 make car door restrictor work as intended. 2.repair leak above unit 1 in elevator equipment room. Finish ceiling above unit one and fire rate. 2.5 clean elevator equipment room. 2.14 install code data tag to controller 1984. 3. clean top of canopy on car top. 3.2 replace elevator car top light. 5.1 install pit ladder to code. Make sump pump operable and install cover on sump hole. Clean pit from trash.1301 Enterprise Way
ViewWO 39767Barnard2021-03-26 00:00:00H019310WingateFAILDeon Firelane1.6 make emergency light work as intended. 2.9 water catch pan above controller must not drain in elevator equipment room. Suggest hard piping into pit sump pump. 2.14 install code data tag to controller 1984. 3. Clean top of canopy of car. 3.2 replace car top light guard. 5.1 clean pit from trash.